Flow Control Vale (FCV) Attributes

  • ID: Unique identifier assigned to this element.
  • Label: Descriptive label for this element.
  • Notes: Additional information about this element.
  • GIS-IDs: List of associated IDs on the GIS/data-source side.
  • Hyperlinks: Associate one or more web link, photo, word processing document, or other file with this element.
  • Flow Setting (Initial): Initial flow setting for the flow control valve.
  • Discharge Coefficient (Transient): Discharge coefficient, Cv, is defined as: Flow / (Pressure Drop) ^ 0.5.
  • Operating Rule: Specifies the operation of the valve during a transient simulation.
  • Flow (Initial, Transient): The initial flow to be used in the transient analysis.
  • Pattern (Valve Settings): Allows you to apply a pattern for changes to the valve's setting over time for extended period simulations. (Note that patterns override settings changes made by controls).
  • Valve Characteristics: Specifies the valve characteristics definition to be used for this valve. If the Valve Characteristic Curve is not defined then a default curve will be used. The default curve will have (Relative Closure, Relative Area) points of (0,1) and (1,0).
  • Valve Type: Choices: Butterfly, Needle, Circular Gate, Globe, Ball, User Defined
  • Status (Initial): Choices: Active, Inactive, Closed
  • Diameter (Valve): Inside diameter of the valve. Used to calculate the velocity through the valve and a corresponding minor loss when a minor loss coefficient is entered.
  • Valve Coefficient Type: Specifies which type of coefficient to enter for the control valve. If entering discharge coefficient, the value is internally converted into an equivalent headloss coefficient (minor loss).
  • Discharge Coefficient (Fully Open): The discharge coefficient of the valve when fully open. Used in lieu of minor loss for valves of this coefficient type.
  • Specify Local Minor Loss?: If True, the minor coefficient for the element is manually set in the Minor Loss Coefficient (Local) field; otherwise the value is derived from the minor loss library.
  • Minor Loss Coefficient (Local): User-input minor loss coefficient. You can either type the value directly in this field or select the value from the minor loss library. The minor loss is applied to the valve when it is fully open (inactive). Note that minor losses do not apply to the following valve types: General Purpose Valve and Valve With Linear Area Change. These two valve types do not support a (fully) open status and always apply the head/flow relationship defined by their headloss curve and discharge coefficient, respectively.
  • Status (Initial, Transient): Choices: Active, Inactive, Closed
  • Elevation: Elevation at centroid of junctions, valves, and pumps; the ground elevation at tanks; the hydraulic grade at reservoirs.
  • Concentration (Initial): Specify the initial concentration for the global concentration at the selected element.
  • Age (Initial): Specify the initial age of the fluid at the selected element.
  • Installation Year: Specify the install year of the element. It does not affect the calculations.
  • Trace (Initial): Specify the initial trace amount at the current location.
  • Zone: Specify the zone for the element.
  • Flow Setting (Calculated): Flow setting at selected valve for current time step.
  • Flow: Total flow through the valve.
  • Velocity: Velocity of flow traveling through the valve.
  • Headloss: Change in head across the valve.
  • Pressure Loss: Change in pressure across the valve.
  • Hydraulic Grade (From): Calculated hydraulic grade at the entrance of the valve.
  • Hydraulic Grade (To): Calculated hydraulic grade at the exit of the valve.
  • Pressure (From): Calculated pressure at the entrance of the valve.
  • Pressure (To): Calculated pressure at the exit to the valve.
  • Flow (Absolute): Magnitude of flow through the selected valve.
  • Status (Calculated): Choices: Active, Inactive, Closed
  • Minor Loss Coefficient (Unified): Displays the current minor loss value for the element, depending on whether its derived or local.
  • Age (Calculated): Age at selected element for current time step.
  • Trace (Calculated): Trace at selected element for current time step.
  • Concentration (Calculated): Concentration at selected element for current time step.
  • Has Calculation Messages Now?: If true then the current element has associated calculation warning messages for the current time step.
  • Is Closed?: True if the current element is closed during the current time step.
  • Is Open?: Set to true if open during the current time step.
  • Is Initially Closed?: If true, the initial condition for the control element is "Closed" or "Off."
  • Controlled?: Is true if a control action in the current control set references the selected element.
  • Cannot Deliver Flow or Head?: If true then the cannot deliver head or cannot deliver flow warning was generated for the element for the current time step.
  • Head (Maximum, Transient): Maximum head at node over the course of the transient simulation.
  • Head (Minimum, Transient): Minimum head at node over the course of the transient simulation.
  • Pressure (Maximum, Transient): Maximum pressure at node over the course of the transient simulation.
  • Pressure (Minimum, Transient): Minimum pressure at node over the course of the transient simulation.
  • Air Volume (Maximum, Transient): Maximum air volume at node over the course of the transient simulation. Not applicable to Reservoirs and Rating curves.
  • Vapor Volume (Maximum, Transient): Maximum vapor volume at node over the course of the transient simulation. Not applicable to Reservoirs and Rating curves.