Pressure Pipe-Physical

Pressure Pipe-Physical Attributes

Attribute Description
Is Virtual? If True, the physical properties will be ignored, except when using the Gradually Varied Flow (GVF) solver. Can be used to connect pumps to nodes without accounting for hydraulic properties.
Diameter The diameter of the cross section of the currently highlighted element.
Material The name of the material used. Alternatively, clicking the ellipsis button opens the Material Engineering Library, allowing you to select a pre-defined material. If a pre-defined material is chosen, the roughness value will change accordingly.
Manning’s n The Manning’s roughness of the currently highlighted element. This field is available only if you selected Mannings as the default Pressure Friction Method in the Calculation Options Manager.
Hazen-Williams C The Hazen-Williams roughness of the currently highlighted element. This field is available only if you selected Hazen-Williams as the default Pressure Friction Method in the Calculation Options Manager.
Darcy-Weisbach e The Darcy-Weisbach roughness of the currently highlighted element. This field is available only if you selected Darcy-Weisbach as the default Pressure Friction Method in the Calculation Options Manager.
Kutter’s n The Kutter’s roughness of the currently highlighted element. This field is available only if you selected Kutters as the default Pressure Friction Method in the Calculation Options Manager.
Elevation (Start Invert) The start, or upstream, invert of the currently highlighted element.
Set Invert to Start Node? Sets the start invert of the current element to the elevation of the start node (upstream). Set this to False to enter a value for the elevation of the invert, or set this field to True to use the start-node elevation.
Elevation (Stop Invert) The stop, or downstream, invert of the currently highlighted element.
Slope The slope.