Bentley StormCAD CONNECT Edition Help

Defining Inflow Collections

You can define an inflow collection for any node element in Bentley StormCAD . An inflow collection can contain any combination of fixed, hydrograph, or pattern inflows. An inflow collection can contain any combination of fixed and hydrograph inflows.

To define an inflow collection:

  1. Click a node element in your model to display the Property Editor, or right-click a node element and select Properties from the shortcut menu.
  2. In the Inflow Collection section of the Property Editor, click the Ellipses (...) button. The Inflow Collection Editor appears.
  3. Click the New button, then select the type of inflow you want to create from the submenu (Fixed Inflow, Hydrograph Inflow, Pattern Inflow).
  4. For a Hydrograph Inflow, enter the data points in the hydrograph table. For Fixed and Pattern Inflows, enter the data in the appropriate fields. For a hydrograph, if the last time in the table is less than the total simulation time, the simulation time and last flow will be appended to the hydrograph table.
  5. Repeat steps 3 and 4 for each inflow you want to add to the collection.
  6. Click the Composite Hydrograph button to see a graph of the composite hydrograph.
  7. Click the Composite HydrographData Table button to see a tabular view of all the data points in the composite hydrograph.
  8. Click OK to close the dialog box and add the collection data to the Property Editor.

Inflow Collection Editor

This dialog box lets you define fixed loads, hydrograph loads, and pattern inflows for any node element. A node may have any combination of fixed loads, hydrograph loads, and pattern inflows.

The dialog box contains an Inflow list pane and the following controls:

     
New Opens a submenu containing the following options: Fixed Inflow —Adds a new Fixed Load inflow to the Inflow list pane. Hydrograph Inflow —Adds a new Hydrograph inflow to the Inflow list pane.
Delete Lets you delete the currently highlighted load.
Report Opens a print preview window containing a report that details the input data for this dialog box.
Composite Graph Opens a graph window plotting a curve of a selected single sanitary load or the composite hydrograph of all loads.
Composite Hydrograph Opens a window listing all the data points in the curve of a selected single sanitary load or in the composite hydrograph of all loads.

The Inflow Collection Editor also contains the following controls:

   
Hydrograph Table Lets you define the hydrograph by entering Time vs. Flow points. This table is available only when a Hydrograph Load inflow is highlighted in the Inflow list pane. If the last time in the table is less than the total simulation time, the simulation time and last flow will be appended to the hydrograph table.
Fixed Load Lets you define a fixed load value. This field is available only when a Fixed Load inflow is highlighted in the Inflow list pane. Set the fixed flow that affects the manhole.
Base Inflow The average inflow over the duration of the simulation.
Inflow Pattern Lets you select the pattern for the selected pattern inflow. Patterns are selected, edited, and created in the Pattern Manager, which you access by clicking the ellipsis (...) button next to this field.