Angle |
Positive <angle value>
- Sets angle between wye side branches.
|
Branch | Connection Length |
Positive <numeric value>
- Sets length of the un-threaded portion of a tee fitting. This is the distance between the main branch centerline to where the threaded portion at EndSpec3 begins.
|
Branch | Connection Length (for Branch Wye) |
Positive <numeric value>
- Sets the straight length at End3.
|
Branch Extension Length |
Positive <numeric value>
- Sets the H branch (End3) straight length between the bend and the start of the end condition, that is parallel to the main branches (End1 and End2).
|
Branch Length |
Positive <numeric value>
- Sets the straight length for the angled portion of the heel (End3), ending at the bend start.
|
Branch1 Outer Diameter |
Positive <numeric value>
- Reduced branch outside diameter.
|
Branch2 Outer Diameter
|
Positive <numeric value>
- Side branch (End3) outside diameter.
|
Center to Branch Distance |
Positive <numeric value>
- Sets distance between main branch center line and End3 connect point.
|
Center to Inlet Distance |
Positive <numeric value>
- Sets distance between End1 connect point and End2 center line.
|
Connection | End Type |
fl -<numeric value>
- Sets and sizes end with a flange connection.
m -<numeric value>
- Sets and sizes end with a male connection.
fe -<numeric value>
- Sets and sizes end with a female connection.
Separate End Type entries for each End Spec with a semi colon. Example: fl-2;fe-.13 creates a flange at End1 with size 2, and a female connection at End2 with an overall reduction of component's dimensions of .13
|
Inlet | Length |
Positive <numeric value>
- Sets the offset distance between the start of the un-threaded portion at EndSpec1 and the tee's third branch center line at EndSpec3.
- Sets the straight length at End1, (for Branch Wye).
|
Inlet to Branch Offset |
Positive <numeric value>
- Sets the distance between the End1 connect point and the End2 center line for trap fittings.
- Sets the distance between the End1 connect point and the divergence point of the heel (End3) center line.
|
Inlet | Outer Diameter |
Positive <numeric value>
|
Outlet | Length (for Branch Wye) |
Positive <numeric value>
- Sets the straight length at End2.
|
Outlet to Branch Vertical Offset |
Positive <numeric value>
- Sets the distance between the main branch (End1/End2) and the heel (End3) center lines.
- Sets the distance between the End1 center line and the trap center line.
|
Radius |
Positive <numeric value>
- Sets center line radii for wye side branches.
|
Total Length |
Positive <numeric value>
- Sets overall length of fitting.
|