Base Offset
|
<numeric value>
- Displays the Base
Offset set in the
Place dialog while placing a pipe. The value
reflects when a pipe is being modified.
|
Cap | Length
|
Positive <numeric value>
- Sets the distance
between the connect point (End1) and the start of the dome.
|
Connection 1 | Length (L1)
|
Positive <numeric value>
- Sets length of
male or female connection for End1. Set End Type to male or female to see
change in geometry. If End Type is flange, the connection point moves.
|
Connection 2 | Length (L2)
|
Positive <numeric value>
- Sets length of
male or female connection for End2. Set End Type to male or female to see
change in geometry. If End Type is flange, the connection point moves.
|
Connection | End Type
|
fl
-<numeric value>
- Sets and sizes
end with a flange connection.
m
-<numeric value>
- Sets and sizes
end with a male connection.
fe
-<numeric value>
- Sets and sizes
end with a female connection.
Separate End Type entries for each End Spec with a semi
colon.
Example: fl-2;fe-.13 creates a flange at End1 with size 2, and
a female connection at End2 with an overall reduction of component's dimensions
of .13
For Flex Bellows
The End Type is either
- 1-Flange – Adds
flanges to both ends.
- 2-Plain – Sets no
flanges to the ends.
|
Dome Height
|
Positive <numeric value>
- Sets the height
of the dome bulge.
|
Female Connection Diameter
|
Positive <numeric value>
- Reduced branch
outside diameter at End2.
|
Inlet | Outer Diameter
|
Positive <numeric value>
- Outside inlet
diameter of socket.
|
Male Connection Diameter
|
Positive <numeric value>
- Main branch
outside diameter at End1 of union fitting.
|
Minimum
Length
|
Positive <numeric value>
- Sets minimum
length. Duct cannot be manipulated to segments smaller than Minimum Length
property.
|
Outlet | Outer Diameter
|
Positive <numeric value>
- Outside outlet
diameter of socket.
|
Pipe
Length /
Total Length (L)
|
Positive <numeric value>
- Sets duct length
with a positive value greater than or equal to value of Minimum Length
property.
- Displays flex
linear length. Set by default.
|
Pipe Outer Diameter
|
Positive <numeric value>
|
Ridge Distance
|
Positive <numeric value>
- Sets the spacing
of ridges.
|
Ridge Numbers
|
Positive <integer>
- Sets the number
of ridges.
|
Slope Method
|
-
Rise/Run
-
Degree
-
% Precent
<active method set in Apply Slope>
- Displays slope
method currently set in the Apply Slope setting.
|
Slope Value
|
<numeric value>
- Displays slope
value appropriate with the active Slope Method.
|