Class Name |
<Class name>
- Set by Manufacturer Catalog dialog when available. Represents database class name.
|
End Condition 1 End Condition 2
|
<End_COND_xx>
- Set by Manufacturer Catalog dialog when available. Represents end conditions at each connect point.
|
Facing |
<Alpha-numeric value>
- Displays flange mating surface face treatment.
|
Flange | Diameter |
Positive <numeric value>
- Sets flange outside diameter for End1 and End2.
|
Flange | Thickness |
Positive <numeric value>
- Sets flange outside diameter for End1 and End2.
|
Gasket Diameter |
Positive <numeric value>
- Sets gasket outside diameter.
|
Gasket Thickness |
Positive <numeric value>
|
Plumbing Connection | Outer Diameter |
<numeric value>
- Sets pipe outside diameter for End1 and End2.
|
Rating |
<Alpha-numeric value>
- Displays flange's primary pressure rating.
|
Setback Distance |
<numeric value>
- Sets connect point offset at End2.
|
Slip-on Diameter |
Positive <numeric value>
- Sets the outside diameter of the slip on portion of the component.
Maximum size restricted by Flange Diameter property. |
Taper Diameter |
Positive <numeric value>
- Sets outside diameter of the tapered end.
Minimum size restricted by Inlet Outer Diameter property. |
Tag |
<alpha-numeric characters>
- For Gasket fitting, sets tag value visible in output of drawing composition in dynamic view. Separate tag strings with a semi colon.
|
Total Length |
Positive <numeric value>
- Sets distance between End1 and End2 of valve.
|