Cabinets
|
BMP_FireHoseCabinet "FireHoseCabinet"
|
Fire Hose Cabinet — Designed to accommodate
different combinations of fire hose racks.
|
BMP_FireHoseReelCabinet "FireHoseReelCabinet"
|
Hose Reel Cabinet — A single door surface
mounted Fire Hose Reel Cabinet designed to accommodate different combinations
of fixed and swinging hose reels fire hose reels.
|
BMP_ReelAndExtinguisherCabinet
"ReelAndExtinguisherCabinet"
|
Hose and Extinguisher Cabinet — Vertical
two-compartment Hose Reel and Extinguishers Cabinet designed to accommodate a
Hose Reel in upper compartment and the lower can house number of fire
extinguishers.
|
BMP_YardHydrantCabinet "YardHydrantCabinet"
|
Yard Hydrant Cabinet — Fire cabinet
suitable to house fire hoses, Jet spray nozzles, Dividing breeching inlet, Fire
axe, Crow bar and Hydrant wrench.
|
BMP_LandingValveCabinet "LandingValveCabinet"
|
Landing Valve Cabinet — Fire cabinet
specially designed to store hydrant landing valves or other equipment.
|
BMP_BreechingInletCabinet "RecessedType_2Way"
|
Breeching Inlet Cabinet – Recessed Type, 2
Way — Breeching Inlet Cabinet is designed to accommodate 2-way 6" Outlet
Breeching inlets, recesses mounting version.
|
BMP_FireExtinguisher "FireExtinguisher"
|
Fire Extinguisher — The fire plug serving a
source of water provided in most living areas with water channeled into the
tap. Used to combat fires by attaching hose to the clapper vales and opened.
|
BMP_FireHydrant "FireHydrant"
|
Fire Hydrant — Portable Fire Extinguisher
with pressure stored dry chemical, Carbon Dioxide (CO2), water or
Foam in the cylinder. Wall mountable.
|
BMP_BreechingInletCabinet "SurfaceType_4Way"
|
Breeching Inlet Cabinet – Surface Type, 4
Way — Breeching Inlet Cabinet to accommodate 4 nos 4" Outlet Breeching inlets,
surface mounting version.
|
BMP_BreechingInletCabinet "SurfaceType_2Way"
|
Breeching Inlet Cabinet – Surface Type, 2
Way — Breeching Inlet Cabinet is designed to accommodate 2-way 6" Outlet
Breeching inlets, surface mounting version.
|
BMP_BreechingInletCabinet "RecessedType_4Way"
|
Breeching Inlet Cabinet – Recessed Type, 4
Way — Breeching Inlet Cabinet is designed to accommodate 4-way 4" Outlet
Breeching inlets, recesses mounting version.
|
Valves
|
BMP_BreechingInlet "BreechingInlet"
|
Breeching Inlet — A 2-way or 4-way
breeching inlet set, installed in front of building accessible to fire engine
to feed water into riser systems via their fire hoses.
|
BMP_ZoneControlValve "Zone Valve"
|
Zone Valve — To control the flow of
saturated steam, hot water, and chilled water through coils and heat exchanger
of all types, in a wide range of HVAC applications.
|
BMP_LandingValve "Type02"
|
Landing Valve with Flange — Landing valve
with flange instead of screwed thread inherit comfort in operation.
|
BMP_LandingValve "Type01"
|
Landing Valve — Simple valves mounted in
all the floor to install hydrant to provide water to extinguish fire by
connecting water hose to that valve.
|
BMP_AlarmCheckValve "Alarm Valve"
|
Alarm Check Valve — Designed expressly for
use in wet pipe (automatic sprinkler) fire protection systems. The valve opens
and allows pressurization of the alarm chamber upon the operation of one or
more automatic fire sprinklers.
|
Sprinklers
|
BMP_SprinklerHeadSideWall "SprinklerHeadSideWall"
|
Sprinkler Head Sidewall — Side wall
sprinkler heads stand out from a wall. They provide a half-circle spray
pattern. A second deflector also sprays water back toward the wall so that the
wall is protected. These are used when sprinklers cannot be located in the
ceiling.
|
BMP_SprinklerHeadUpright "SprinklerHeadUpright"
|
Sprinkler Head Upright — Upright sprinkler
heads project up into a space. They are generally used in mechanical rooms or
other inaccessible areas to provide better coverage between obstructions. They
also provide a circle spray pattern.
|
BMP_SprinklerHead "SprinklerHead"
|
Sprinkler Head — Sprinkler is the
component of a fire sprinkler system that discharges water when the effects of
a fire have been detected, such as when a predetermined temperature has been
exceeded. Can set type Extended or Recessed and can have cap or no cap.
|