RAM Structural System Help

Applied Loads

The axial load, moment, and shear force acting at the base of a column is applied to the continuous footing at the centerline of the column.

The uniform surcharge loads on the footing are defined as uniform line loads on the finite beam elements. This assumes that the supported columns and walls occupy a small portion of the total footing surface area.