RAM Structural System Help

Design Principles

The factors used for force adjustment in the RAM Concrete Wall module are based on the table below.

Member Type SI 9,I I II III Notes
The wall in transframe Strengthen story and above story M 1.8 1.5 1.5 1.25 1.0 (10.2.14) (7.2.10)
V 1.9 1.7* 1.6 1.4 1.2
Non-Strengthen story M 1.3 1.2 1.2 1.0 1.0 (7.2.6) (4.9.2)
V 1.2 1.0 1.0 1.0 1.0
Normal Frame Strengthen story and above story M 1.1 1.0 1.0 1.0 1.0 (7.2.10) (4.9.2-4)
V 1.9 1.7* 1.6 1.4 1.2
Non-Strengthen story M 1.2*1.1 1.2 1.2 1.0 1.0 (7.2.6) (4.9.2)
V 1.2 1.0 1.0 1.0 1.0
Tall Building Strengthen story and above story M 1.1 1.0 1.0 1.0 1.0 (7.1.2)
V 1.9 1.7 1.6 1.4 1.2
Non-Strengthen story M 1.3 1.2 1.2 1.0 1.0 (7.2.6) (4.9.2) (7.1.2)
V 1.2*1.4 1.0*1.4 1.0*1.4 1.0*1.2 1.0
Note: For the seismic grade 9, the shear-force factor 1.7 is used. Clause 6.2.8.