Loading Information ‑ Point Loads

SettingDescription
Dist This is the location of the point load represented as a distance measured from the left end of the beam.
DL This is the magnitude of the dead load.
CDL This is the magnitude of the construction (pre‑composite) dead load.
RedLL This is the magnitude of the unreduced reducible live load.
NonRLL This is the magnitude of the non‑reducible live load.
StorLL This is the magnitude of the storage live load.
RoofLL This is the magnitude of the unreduced roof live load.
Red% This is the amount of live load reduction allowed for the corresponding Live Load Type, based on the currently selected building code. For Roof Live Loads, if the roof live load has been specified as a snow load, "snow" will appear in lieu of a reduction percent.
CLL This is the magnitude of the construction live load.
PartL This is the magnitude of the partition live load.