Assign Fixity

The engineer can assign fixity to beams, columns, horizontal braces or vertical braces by selecting the Assign - Beam - Fixity, Assign - Column – Fixity, Assign – Horizontal Brace - Fixity or Assign - Brace - Fixity commands respectively. From the dialog that appears the engineer should select the appropriate fixity conditions.

After the appropriate fixity is selected the engineer can assign this fixity condition to a single member (click on Single), to multiple members (click on Fence) or to all members (click on All). If Single is selected the dialog will close and a target cursor will be made available. Click on each member to assign fixity. If Fence is selected the dialog will close and a fence cursor will be made available. Click and drag a rectangle around all the members to assign fixities. Note that fixity is only assigned to members comprised of the same type (beam, column or brace) as the menu command issued.