Reinforcement
This section contains the pertinent information for the reinforcement in the footing. Top reinforcement is only reported if required for the footing.
Setting | Description |
---|---|
Required Steel/Provided Steel | The required steel may be controlled by either the moment at the critical section or the minimum code required/user defined flexure reinforcement. |
Bar Spacing | This is the actual center to center bar spacing using the footing dimension minus the cover on each side. |