Assign Wall Groups
The RAM Frame integrates the contribution of member forces from these wall panels and columns into a single member force for the wall group. This command is useful to arrive at design member forces (such as shears, moments, and torsion) for a whole wall group unit.
command is used to group columns and shear wall panels into a single wall system (wall group).The
command is used to define the wall group number. The numbers are limited between 0-999. The command is used to select walls and or columns that form part of the wall group.The major direction of a wall group is determined by the orientation of the last wall panel selected for the particular wall group. The major direction for a particular wall group can be changed at any time by clicking on a wall panel that lies in the desired direction.
The Single or Fence mode.
command can be used in the