Hanging Columns

In addition to the I-Section, Rectangular, and Round HSS shapes available for both standard and hanging columns, channels, single angles, double angles, tees, round bars and flat bars can be assigned to hanging columns. The table below describes how each of the design codes handle hanging columns subjected to different load types.

Design Code Channel Single Angle Double Angle Tee Round Bar Flat Bar
AISC 360 ASD

AISC 360 LRFD

AB AB AB AB TO AB
ASD 9th Edition

LRFD 3rd Edition

CAN/CSA S16

BS5950:1900

BS5950:2000

Eurocode

AB TO AO AO TO TO
IS 800-07 AB TO AO AO (see note) (see note)
Note: Round bars, flat bars, built-up channels, and built-up tube shapes are not currently designed to the IS 800-07 design code.
SettingDescription
TO Shape under Tension-Only loads can be designed using selected code.
AO Shape under Axial-Only (Tension or Compression) loads can be designed using selected code.
AB Shape under Axial and Bending loads can be designed using selected code.