Hanging Columns
In addition to the I-Section, Rectangular, and Round HSS shapes available for both standard and hanging columns, channels, single angles, double angles, tees, round bars and flat bars can be assigned to hanging columns. The table below describes how each of the design codes handle hanging columns subjected to different load types.
Design Code | Channel | Single Angle | Double Angle | Tee | Round Bar | Flat Bar |
---|---|---|---|---|---|---|
AISC 360 ASD
AISC 360 LRFD |
AB | AB | AB | AB | TO | AB |
ASD 9th Edition
LRFD 3rd Edition CAN/CSA S16 BS5950:1900 BS5950:2000 Eurocode |
AB | TO | AO | AO | TO | TO |
IS 800-07 | AB | TO | AO | AO | (see note) | (see note) |
Note: Round bars, flat bars,
built-up channels, and built-up tube shapes are not currently designed to the
IS 800-07 design code.
Setting | Description |
---|---|
TO | Shape under Tension-Only loads can be designed using selected code. |
AO | Shape under Axial-Only (Tension or Compression) loads can be designed using selected code. |