ACI-318 2014
This section discusses the features that are implemented or changed due the implementation of ACI 318-14 within the RAM Concrete Wall module and the assumptions made by the program when selecting this ACI Code.
Number of Curtains of Reinforcement
ACI 318-14 (18.10.2.2) |
= | ||
= | ||
= | ||
= |
RAM calculates the parameter Acv as the product of the thickness and the length of the section. For λ, the program considers the value for normal weight concrete.
The parameter lw as the overall horizontal dimension of the wall panel or core as measured in the direction of loading for a specific load combination (see Dimensional assumptions for calculation of limiting c value per ACI 318-11, Eq 21-8).
The parameter hw is taken as the vertical distance from the bottom of the story at which the Section Cut is located to the overall top of the Wall Design Group.
Special Boundary Element Check
Displacement method
ACI 318-14 (18.10.6.2) |
RAM Concrete Wall evaluates the limiting boundary neutral axis calculation only when ACI 318-14 (18.10.6.2) meets.
Stress-based method
ACI 318-14 (18.10.6.3) |
= |
Limiting Boundary Neutral Axis Calculation
RAM Concrete Wall performs the check of the neutral axis depth according to ACI 318-14, 18.10.6.2. This Section code states that compression zones shall be reinforced with special boundary elements when:
ACI 318-14 (18.10.6.2) |
= | Largest neutral axis depth calculated for the factored axial force and nominal moment strength consistent with du. |
lw, d u, d e, Cd, hw, and c are defined in 7.7.1.
Minimum boundary thickness
RAM Concrete Wall checks the boundary thickness according to ACI 318-14 Sec. 18.10.6.4 (b) and (c). For each section cut, where boundary is required, the program considers the following requirements:
ACI 318-14 18.10.6.4 (b) |
ACI 318-14 18.10.6.4 (c) |
= | ||
= |
hw, lw, and c are defined in Section Limiting Neutral Axis Calculation .